TY - JOUR T1 - Research about Contrast Media Volume Injection by Body Mass Index in Cardiac CT AU - Kim, Kyoo-Hyung AU - Lim, Chung-Hwan JO - Journal of Engineering and Applied Sciences VL - 12 IS - 14 SP - 3557 EP - 3560 PY - 2017 DA - 2001/08/19 SN - 1816-949x DO - jeasci.2017.3557.3560 UR - https://makhillpublications.co/view-article.php?doi=jeasci.2017.3557.3560 KW - MDCT KW -contrast side effect KW -BMI KW -SNR KW -contrast media AB - Even a little smaller amount of contract medium is used for cardiac CT according to patient’s BMI, excellent image with high HU and SNR can be obtained. CT equipment used in this study was light speed volume CT 64 channel (GE healthcare, USA). Patients with heart rate <65 were classified into 4 groups according to their BMI and SNR was measured by injecting different amount of contrast media. Collected materials were analyzed using SPSS 23.0 Ver. at the significance level of p<0.05. By BMI, measured value was the highest at underweight and the lowest at extreme obese. By contrast media dose, it was the highest at 90 mL and the lowest at 80 mL. Correlations analysis of variance showed statistically significant difference according to contrast media dose by BMI. It is considered that contrast medium does should be decided considering BMI to minimize side effects of contrast medium while acquiring excellent quality SNR. ER -