A.O. Akinro , M.O. Alatise and O.O. Olanrewaju
Page: 1470-1475 | Received 21 Sep 2022, Published online: 21 Sep 2022
Full Text Reference XML File PDF File
The yield and the reservoir capacity of River Owena in Ondo State were estimated using a combination of the Rippl`s mass curve and the Loucks Sequent Peak Procedure. The yield was found to be 299.99x106m3. However, the reservoir capacity obtained from the mass curve was 125x106m3. This is lower than the yield value and if used for the dam design, there will be a danger of the reservoir capacity not being able to meet the expected demand. Further analysis was done using the Loucks Sequent Peak Procedure. The value from this procedure was 3.30x109m3. This capacity is safe and reliable and will ultimately meet the water demand of the people in the coverage area.
A.O. Akinro , M.O. Alatise and O.O. Olanrewaju . Combining Rippls` Mass Curve and Loucks Sequent Peak Procedureto Determine Reservoir
Capacity: The Case Study of Owena River in Ondo State, Nigeria.
DOI: https://doi.org/10.36478/jeasci.2007.1470.1475
URL: https://www.makhillpublications.co/view-article/1816-949x/jeasci.2007.1470.1475